Description:ICS Triplex T8850C is a 40-Channel Analog or Digital Output FTA for versatile signal control.
Product condition: New
Packing condition:Factory Packing
100% insured shipping: A guarantee for your purchases
PLC Autocontroller DELIVER PARTS TO WORLD.
Manufacturer | ICS triplex |
Item number | T8850C |
Country of Origin | United States |
Lead Time | In stock |
After-Sales Support | 12-months |
HS Code / Commodity code | 8537101190 |
Quotes are valid for 30 days from the day the quote is received unless stated otherwise at the time of quotation.
Yes,we offer one year warranty for all new products.
Yes. We worked with FEDEX/DHL/TNT/UPS/ allowing us to provide swift global delivery of parts to any corner of the world.
Normally 3-5 working days,some remote areas 5-7 days more.
T8850C keeps the same 40-channel, software-selectable analog-or-digital soul as T8850, but adds: • Cold-start surge clamp – loop cards no longer dip when field power is re-applied
• Conformal-coated PCB (IPC-610-3C) – 5× salt-fog life, perfect for offshore or coastal skids
• Cable-saving “C-coded” spring terminals – accept 0.34 mm² up to 2.5 mm² without ferrules
• Configurable group-level OVP (Over-Voltage Protection) – 28 V, 32 V, 36 V trip via TriStation 1131 v4.9
• Certified for IEC 61326-3-2:2021 EMC – immunity to 30 V/m radiated field, 2 kV surge on signal lines
side-by-side table
Feature / Spec |
T8850 (legacy) |
T8850C (current) |
PCB coating |
None |
Full conformal, 50 µm |
Salt-fog endurance |
96 h |
500 h (ASTM B117) |
Spring terminal range |
12-28 AWG |
0.34-2.5 mm² (22-14 AWG) |
Max radiated immunity |
10 V/m |
30 V/m |
Group OVP setting |
Fixed 33 V |
TriStation-selectable 28/32/36 V |
Cold-start surge clamp |
No |
Yes (< 5 A inrush limit) |
Housing color |
Light gray |
Anthracite gray |
LED indication |
Single color |
Dual-color + flash code |
TriStation minimal version |
v4.6 |
v4.9 |
RoHS |
RoHS 5/6 |
RoHS 10/10 |
Availability (PLC Autocontroller stock) |
Last-buy phase |
Active production |
Where the “C” scores money Offshore platforms: coating + salt-fog = 8 extra years before first deck-box replacement.
OEM skid builders: selectable OVP lets you use the same FTA for 24 Vdc solenoids AND 28 Vdc sounder beacons—one SKU instead of two.
Retrofit jobs: anthracite color instantly tells technicians “new revision—check TS1131 version”, reducing mis-wiring tickets.
Quick-fit compatibility • Rack: same 110 × 360 mm DIN-rail cut-out – drop-in swap.
• Cable schedule: identical core numbers; only outer jacket diameter can increase by 0.2 mm due to C-coded key.
• Logic: TMR lane mapping unchanged; TriStation project needs v4.9+ to see OVP menu.
What happens next?